Mitsubishi MSY-GF24VA Product Introduction
Origin: Thailand
Energy Efficiency Label: Level 1
Maintenance period: 2 years
Registration and maintenance method: Please register online for warranty within ten days after purchase, https://www.mitsubishielectric.com.hk/customer-services/warranty?cat=0
Overview
Frequency conversion control, cooling sensation control, somatosensory control, independent computer dehumidification, powerful refrigeration operation, automatic up and down swing air supply (7 options)
Automatic left and right swing air supply, wide-angle and long-distance air supply, automatic closing air deflector, nano-platinum ceramic filter, open cleaning design, self-diagnosis
i-Save/Easy control/Smart settings
LCD wireless remote control preset switch time switch (24 hours/week)
Anti-rust coating technology protects the circuit and automatically restarts#
#The automatic restart function must be started and set up by qualified engineering personnel. If your customer needs technical support from our company, you can contact our company's maintenance service center.
Product Specifications <br data-mce-fragment="1">Model
Indoor unit: MSY-GF24VA
Outdoor unit: MUY-GF24VA
Cooling/heating capacity
Operating Mode: Net Cooling Rating (kW): 6.6
Minimum and maximum values (kW): 2.4-8.7
Rating (BTU/h): 22519
Minimum and maximum values (BTU/h): 8189-29684
power consumption
Rating (kW): 1.83
Minimum and maximum values (kW):-
Operating current (A): 8.6
Air flow (m³/min.): 17.8
Energy efficiency value: 3.61
Noise value
Indoor (high/low) dB(A): (30)-37-41-45-49
Outdoor (high) dB(A): 55
Dimensions (height x width x depth) indoor unit (mm): 325x1100x238
Outdoor unit (mm): 880x840x330
net weight
Indoor unit (kg): 16
Outdoor unit (kg): 53
Diameter of connecting conduit liquid (mm): 9.52
Gas (mm): 15.88
Voltage (V): 220
Phase/frequency: single phase/50 Hz Refrigerant type: R410A
Indoor unit color: white Test conditions:
Cooling - 27ºC DB / 19ºC WB indoors; 35ºC DB / 24ºC WB outdoors.
Heating - 20ºC DB / 15ºC WB indoors; 7ºC DB / 6ºC WB outdoors.
Note: DB (dry bulb temperature), WB (wet bulb temperature)