Mitsubishi Heavy Mitsubishi Heavy Industries SRK35MWKH1 Product Introduction
made in China
Energy Efficiency Label: Level 1
Dimensions: Height 289 mm X Width 798 mm X Depth 230 mm
Maintenance period: 3 years
model
SRK35MWKH1 (indoor unit)
SRC35MWKH1 (outdoor unit)
Features
The 1.5 HP variable frequency outdoor heating and cooling unit has a slim body and is suitable for most window sills in Hong Kong, which can save the cost of building a tent. It has built-in UV-C ultraviolet light purification technology to inhibit bacteria and viruses in the air. It has multiple mechanisms and is antibacterial, anti-mildew, and deodorizing. Antibacterial surface fan Intelligent anti-mildew wind, thoroughly drying the water vapor in the machine. Anti-allergen cleaning system. Anti-bacterial, anti-mildew and deodorizing triple filter system. Patented jet air flow technology to achieve large air volume, low vibration and low noise.
6 regional intelligent air supply modes
Wi-Fi smart remote control operation
PP PLUS aerospace-grade variable-mode frequency conversion technology and full DC frequency conversion technology, saving more electricity and money
Product Specifications Cooling Capacity: 11,089 Btu/hr, 3.25 kW
Heating Capacity: 14,365 Btu/hr, 4.21 kW
Power consumption: cooling 0.92 kW; heating 1.15 kW
Operating current: cooling 4.3 A; heating 5.3 A
Power supply: 220V/1Ph/50Hz
Air flow: 8.7 cubic meters per minute for cooling; 9.7 cubic meters per minute for heating Dehumidification capacity: 2.0 liters per hour Noise: Indoor unit - cooling 21 - 38 dB(A); heating 23 - 38 dB(A)
Noise: Outdoor unit - 51 dB(A)
Product Dimensions: Indoor Unit - 289 x 798 x 230 Height x Width x Depth (mm)
Product Dimensions: Outdoor Unit - 420 x 780 x 290 H x W x D (mm)
Net weight: indoor unit - 10.5 kg Net weight: outdoor unit - 29.5 kg Refrigerant type: R410A
Refrigerant pipe diameter: liquid φ6.35 mm; gas φ9.52 mm Maximum pipe size: height difference 5 meters; length 15 meters Energy efficiency level: 1
COP energy efficiency value: cooling 3.53; heating 3.66
#Refrigerant piping interface location